![]() |
SVGA Electronic Cable
|
Basic construction of the VGA Cable and the SVGA Cable uses 30 AWG stranded tinned copper conductor with cellular Polyolefin insulation. Twisted pairs (or discrete wires) are cabled with coaxes and shielded. The VGA cable & SVGA cable are jacketed with Pebble Gray PVC.*
NOTE: *Pebble Gray (850) is the standard jacket color for this product but other colors are available upon request.
| Series No. Description |
Coax | Insul. Nom. OD | Misc. Cond. |
Shield | Imp. (Ω) Nom. |
Capacitance (pF/ft.) Nom. |
Prop. Delay ns/ft. |
Conductor Resistance Ω/Mft. @ 20°C |
Attenuation (Coax) Nom. |
||
| Inch | mm | MHz | dB/Cft. | ||||||||
| 49020 3 Coaxes 1 purple 1 Blue 1 Red+ 4 Discrete |
30 AWG (7/38) TC |
Foamed Polyolefin |
28 AWG (7/36) TC |
(Coax) 38 AWG TC 85% Braid (Overall) AL/PET tape +36 AWG TC 85% Braid |
75 | 17 | 1.33 | 105.8 | 1 5 10 50 100 200 300 |
0.88 1.52 2.26 4.68 7.00 10.28 13.02 |
|
| 0.0581 | 1.473 | ||||||||||
| Coax Jacket PVC |
|||||||||||
| 0.0972 | 0.464 | ||||||||||
| 48969 3 Coaxes 1 purple 1 Blue 1 Red + 5 Twisted Pair |
30 AWG (7/38) TC |
Foamed Polyolefin |
28 AWG (7/36) TC |
(Coax) 38 AWG TC 85% Braid (Overall) AL/PET/AL tape +36 AWG TC 85% Dual Braid |
75 | 17 | 1.33 | 105.8 | 1 5 10 50 100 200 300 |
1.8 2.5 5.7 8.0 13.0 |
|
| 0.058 | 1.473 | ||||||||||
| Coax Jacket PVC |
|||||||||||
| 0.097 | 2.464 | ||||||||||
| Part No. | No. of Coaxes |
No. Misc. Conductors |
Coax Colors |
Jacket OD (Nom.) | |
| Inches | mm | ||||
| 49020-7-850-S-01000 | 3 | 4 (discrete) | RED, BLU, GRN | 0.300 | 7.620 |
| 48969-13-850-S-01000 | 3 | 10 (5 pair) | RED, BLU, GRN | 0.382 | 9.703 |
| <90ppm | <5ppm | <5ppm | <5ppm | <1000ppm |
| Pb | Cd | Cr+6 | Hg | PBDE's PBB's |
Hitachi Cable Manchester is making every effort to provide Lead free and Cadmium free products to help protect our environment. To this end Hitachi Cable Manchester, Inc. has adopted RoHS (Restriction of Hazardous Substances) as its standard. Hitachi's website Eco-Index is designed to inform the interested user of contents of various restricted or banned elements in terms of parts per million. In most cases, the numbers stated are from actual lab tests using the acid digestion method, considered to be the most severe measurement of analyzing content of restricted and banned elements. It is Hitachi's goal to be 100% compliant to European RoHS, including the removal of the Deca-BDE exemption dated July 1, 2008.
| Region | USA | Global |
| Dist Name | Anixter Inc. | Anixter Wire & Cable EMEA Headquarters |
| Address | 2301 Patriot Boulevard | Unit A, The Beacons Birchwood Park, Risley, Warrington |
| City | Glenview | Cheshire, WA3 6GP |
| State | IL | N/A |
| Zip | 60026-8020 | N/A |
| Country | USA | England |
| Telephone | +1-224-521-4466 | +44 (0) 1925 848017 |
| Fax | +1-432-765-0198 | +44 (0) 1925 850411 |
| Contact | Contact |