SCSI 2 Cable - Round SCSI Cable - Hippi Cable

28 Gauge SCSI 2 Electronic & HiPPI Cable

Bulk 28 Gauge SCSI Cable

UL/CSA Listings: (UL) CMG c(UL) 75°C
Meets UL 444 FT-4 Burn requirements


  • Features
  • Physical Description
  • Applications
  • Specifications
  • Eco-Index

SCSI 28 AWG Cable Features

  • Band-Marked for high-density termination
  • High density and/or VHDCI compatible
  • Round, smooth and firm for overmolding
  • Meets ANSI X3T.9 (Project 0375M Publishes Ref. X3-131-1994) and X3T.10 (Per ANSI X3T.10 Document: 855 Annex D) Standards for interconnection of SCSI devices
  • Harmonized CMG listed for safety

28 Gauge SCSI Electronic Cable Description

Basic construction of the SCSI 2 cable uses 28 Gauge (AWG) solid or stranded conductors with FRPP insulation. Conductors are then twisted into pairs with varying left-hand lays to reduce crosstalk. The required number of pairs are cabled with a left-hand lay, wrapped with a foam polypro tape. The cable is then dual shielded with an AL/PET tape (aluminum side out) and braid shield (A 28 AWG drain wire is inserted between the two shields). The SCSI 2 wire is then jacketed in a CMG rated PVC jacket.†

† Black (000) is standard for this product but other colors are available upon request.

28 AWG SCSI Cable Applications

  • Parallel PC processing
  • High speed interconnect CPU management
  • Board to board interface
  • Ultra 640 (40426), Ultra 320, Ultra 160
  • Fast 80, Fast 40, Fast 20, Fast 10, Fast 5
  • Storage array systems
  • Blade storage devices
  • HDD (High Density Disks)
  • Parallel SCSI, Ultra SCSI and Fast SCSI
  • RAID Devices

28 Gauge SCSI Cable Specifications


Series No. Conductor Insulation Nom. Primary OD Tape Braid Drain Jacket
Inches mm
48331 28 AWG
7/36
TC
Flame
Retardant
Polypropylene
0.028 0.710 100%
Polypro Tape
& AL/PET
80%
Coverage
36 AWG
28 AWG
7/36
TC
PVC
Black
48213 0.034 0.684
48360 Flame
Retardant
Cellular
Polyolefin
0.034 0.889
48212 0.035 0.889
40426 28 AWG
1/28 TC
0.028 0.711 85% Coverage
38 AWG
Series No. Conductor
Resistance
Ω/Mft. @20°C
Capacitance Nom. SE
Imp. (Ω)
Nom.
Diff**
Imp. (Ω)
Prop. Delay
pf/ft. (G-S) pf/ft (G-S-G) ns/ft. Max Delta
ns/ft
48331 67 14 25 62 105 1.50 0.045
48213 10 19 80 123 1.50 0.045
48360 10 19 90 132 1.54 0.040
48212 8 15.5 90 135 1.40 0.045
40426 10 17 90 125 1.35 0.025

Part No. No. of Conductors No. of
Pairs
Core Layout Jacket OD Color Code
Inches mm
48331-50-000-S-01000 50 25 13-9-3 0.366 9.296 Band Marked
48331-68-000-S-01000 68 34 18-11-5 0.402 10.211 Band Marked
48331-100-000-S-01000 100 50 22-16-9-3 0.489 12.421 Band Marked
48213-50-000-S-01000 50 25 13-9-3 0.403 10.236 Band Marked
48213-68-000-S-01000 68 34 18-11-5 0.448 11.379 Band Marked
48360-50-000-S-01000 50 25 13-9-3 0.440 11.176 Band Marked
48360-68-000-S-01000 68 34 18-11-5 0.478 12.141 Band Marked
48212-50-000-S-01000 50 25 13-9-3 0.442 11.227 Band Marked
48212-68-000-S-01000 68 34 18-11-5 0.480 12.192 Band Marked
40426-68-000-S-01000 68 34 18-11-5 0.388 9.855 Band Marked

* The 50 pair 48331 series cable is compliant with High Performance Parallel Interface (HiPPI).
** Measured Shield floating.

Bulk 28 Gauge SCSI Cable RoHS Eco-Friendly Index

<90 ppm <5 ppm <5 ppm <5 ppm <1000 ppm
Pb Cd Cr+6 Hg PBDE's
PBB's

Hitachi Cable Manchester is making every effort to provide Lead free and Cadmium free products to help protect our environment. To this end Hitachi Cable Manchester, Inc. has adopted RoHS (Restriction of Hazardous Substances) as its standard. Hitachi's website Eco-Index is designed to inform the interested user of contents of various restricted or banned elements in terms of parts per million. In most cases, the numbers stated are from actual lab tests using the acid digestion method, considered to be the most severe measurement of analyzing content of restricted and banned elements. It is Hitachi's goal to be 100% compliant to European RoHS, including the removal of the Deca-BDE exemption dated July 1, 2008.