Coax: 36, 38, or 40 AWG conductor insulated with PFA or FEP is shielded then sheathed in either PET or FEP. Twin-Ax: 36 or 40 AWG conductors are insulated with PFA or FEP, laid parallel and braided. A PET tape is helically applied over the braid shield.
| Part No. | Inner Conductor | Dielectric | Shield | MCX™ Sheath | Cap. pF/ft. (pF/m) |
Imp @ TDR (Ω) |
Cond. Resist. Ω/Mft. @ 20°C (Ω)/km) |
||||
| AWG (Stranding) |
Coating | Material | Dia. Inch (mm) |
AWG Braid |
Material | Dia. Inch (mm) |
Color | ||||
| 40327-1-200-S-03000 | 36 (7/44) | TC Alloy |
PFA | 0.0106 (0.27) |
TC + CU met.Tape |
PET | 0.013 (0.34) |
Red | For Power |
30 | 590 (1900) |
| 40327-1-400-S-03000 | Yellow | ||||||||||
| 40327-1-600-S-03000 | Blue | ||||||||||
| 40327-1-000-S-03000 | Black | ||||||||||
| 40232-1-200-S-03000 | 38 (7/46) | SC Alloy |
FEP | 0.0134 (0.34) |
TC + CU met. Tape |
PET | 0.017 (0.44) |
Red | 29 (95) |
50 | 914 (3000) |
| 40232-1-400-S-03000 | Yellow | ||||||||||
| 40232-1-600-S-03000 | Blue | ||||||||||
| 40232-1-000-S-03000 | Black | ||||||||||
| 40311-1-400-S-03000 | 40 (7/48) | SC Alloy |
PFA | 0.0098 (0.25) |
TC + CU met. Tape |
PET | 0.013 (0.34) |
Blue | 30 (100) |
50 | 1524 (5000) |
| 40311-1-600-S-03000 | Yellow | ||||||||||
| 40311-1-000-S-03000 | Black | ||||||||||
| 40331-1-600-S-03000 | 40 (7/48) | SC Alloy |
PFA | 0.0091 (0.23) |
TC | FEP | 0.015 (0.37) |
Blue | 34 (110) |
50 | 1524 (5000) |
| 40331-1-000-S-03000 | Black | ||||||||||
| Part No. | Inner Conductor |
Inner Insulation |
Outer Cond | Shield | Jacket | Cap. pF/ft. (pF/m) |
Imp @ TDR (Ω) |
Max Cond. Resist. @ 20°C (Ω)/km) |
||||
| AWG | Type | Material | Material | Dia. (mm) | Material | Material | Material | Dia. Inches (mm) |
||||
| 40353-2-600-S-01000 | 36 | 7/44 | Silver Cu Alloy | FEP | (0.35) | Tinned | Cu Tape | PET | 0.023 x 0.0373 (0.58 x 0.95) |
54 | 100 | (1,900) |
| 40352-2-700-S-01000 | 40 | 7/48 | Tinned Alloy | PFA | (0.21) | Tinned | Cu Tape | PET | 0.016 x 0.024 (0.4 x 0.61) |
48 | 100 | (5,000) |
| <90ppm | <5ppm | <5ppm | <5ppm | <1000ppm |
| Pb | Cd | Cr+6 | Hg | PBDE's PBB's |
Hitachi Cable Manchester is making every effort to provide Lead free and Cadmium free products to help protect our environment. To this end Hitachi Cable Manchester, Inc. has adopted RoHS (Restriction of Hazardous Substances) as its standard. Hitachi's website Eco-Index is designed to inform the interested user of contents of various restricted or banned elements in terms of parts per million. In most cases, the numbers stated are from actual lab tests using the acid digestion method, considered to be the most severe measurement of analyzing content of restricted and banned elements. It is Hitachi's goal to be 100% compliant to European RoHS, including the removal of the Deca-BDE exemption dated July 1, 2008.