Skip to main content

Hitachi Cable Manchester is an OEM Bulk Cable Manufacturer of Fiber Optic Cable, Premise Cable, Electronic Round Cable, Electronic Ribbon Cable and Custom Wire Cable

Hitachi

bulk cable
Channel Matrix Infiniband Cables

Infiniband & SFP+ SDR / DDR / QDR Cable (Channel Matrix II)

RoHS Compliant Channel Matrix Infiniband Wire CableChannel Matrix II Cable

UL/CSA Style: 20276 VW-1
UL/CSA Voltage Rating: 30 Volts
UL/CSA Temp: 80°C


  • Features
  • Physical Description
  • Applications
  • Specifications
  • Eco-Index

Channel Matrix II Cable Features

  • True Cabled Design for Greater Flexibility
  • Dimensions Compatible with QSFP & CX4 Connectors
  • Heat Bonded Tapes for Channel Isolation
  • Attenuation "suckout" Outside of 10 Ghz

Channel Matrix II Cable Description

Basic construction of these Infiniband cables consists of 8 parallel-pairs cabled round. An overall AL/PET tape and braid shield are electrically isolated from the transmission pairs. A flexible PVC jacket completes the design.

Channel Matrix II Cable Applications

  • Infiniband Architecture - SDR (Single Data Rate), DDR (Double Data Rate) and QDR (Quad Data Rate)
  • Low Skew Applications
  • Differential Pair Applications
  • PCI Express
  • CX4 10 GB Ethernet Applications

Channel Matrix II - Infiniband DDR/QDR 4X Cable Specifications

Download PDF Specifications on Channel Matrix Infiniband Wire Cables

Part No. Cond. Dielectric
Material
Nom. Primary OD
inches (mm)
Pair Shield
Tape
Outer Tape Braid Jacket Cond.
Resis.
Ω/Mft. @20°C
IPS* PtPS** Nom. Diff
Imp. (Ω)
Typical Attenuation
dB/m
1.25 Ghz 2.5 Ghz 5.0 GHz 10 GHz
41027-16 30 (1/30) SPC 3 Layer Flometrics PE 0.029 (0.737) 30 AWG
SPC Drain With Spiral Foil Tape (in) /PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.310 10 ps/m 50 ps/m 100 ±5 1.65 2.47 4.16 8.39
41025-16 28 (1/28) SPC 3 Layer Flometrics PE 0.035 (0.889) 30 AWG
SPC Drain With Longitudinal Foil Tape (in) /PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.207 10 ps/m 50 ps/m 100 ±5 1.28 2.15 3.80 7.40
41026-16 26 (1/26) SPC 3 Layer Flometrics PE 0.044 (1.118) 28 AWG
SPC Drain With Longitudinal Foil Tape (in)/PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.130 10 ps/m 50 ps/m 100 ±5 1.07 1.79 3.24 6.18
41028-16 24 (1/24) SPC 3 Layer Flometrics PE 0.056 (1.422) 26 AWG
SPC Drain With Longitudinal Foil Tape (in)/PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.082 10 ps/m 50 ps/m 100 ±5 0.89 1.70 2.85 5.80

* In-Pair-Skew
** Pair to Pair Skew

Part No. Cond. Dielectric
Material
Nom. Primary OD
inches (mm)
Pair Shield
Tape
Outer Tape Braid Jacket Cond.
Resis.
Ω/Mft. @20°C
IPS* PtPS** Nom. Diff
Imp. (Ω)
Typical Attenuation
dB/m
1.25 Ghz 2.5 Ghz 5.0 GHz 10 GHz
41038-4 30 (1/30) SPC 3 Layer Flometrics PE 0.029 (0.737) 30 AWG
SPC Drain With Spiral Foil Tape (in) /PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.310 10 ps/m 50 ps/m 100 ±5 1.65 2.47 4.16 8.39
41040-4 24 (1/24) SPC 3 Layer Flometrics PE 0.056 (1.422) 26 AWG
SPC Drain With Longitudinal Foil Tape (in)/PET
AL/PET 85%
TC, 38 AWG
Flex PVC 0.082 10 ps/m 50 ps/m 100 ±5 0.89 1.70 2.85 5.80
Part No. IB
Config.
No. of
Pairs
Recommended
Min. bend radius
Inch (mm)
Jacket OD
Inch (mm)
41027-16-000-S-01000 4X 8 2.50 (63.50) 0.245 (6.22)
41025-16-000-S-01000 4X 8 3.00 (76.20) 0.275 (6.98)
41026-16-000-S-01000 4X 8 3.50 (88.90) 0.320 (8.12)
41028-16-000-S-01000 4X 8 4.00 (101.60) 0.375 (9.52)
Part No. SFP+
Config.
No. of
Pairs
Recommended
Min. bend radius
Inch (mm)
Jacket OD
Inch (mm)
41038-4-000-S-01000 4X 2 0.175 (4.45) 0.154 (3.91)
41040-4-000-S-01000 4X 2 0.275 (6.99) 0.236 (5.99)

Due to the infancy of Infiniband in the industry, design and dimensions are subject to change. Please contact Hitachi Cable Manchester for the most recent specifications. All electrical values based on cable performance only – not finished assembly.

Bulk Infiniband Cable RoHS Eco-Friendly Index

<90ppm <5ppm <5ppm <5ppm <1000ppm
Pb Cd Cr+6 Hg PBDE's
PBB's

Hitachi Cable Manchester is making every effort to provide Lead free and Cadmium free products to help protect our environment. To this end Hitachi Cable Manchester, Inc. has adopted RoHS (Restriction of Hazardous Substances) as its standard. Hitachi's website Eco-Index is designed to inform the interested user of contents of various restricted or banned elements in terms of parts per million. In most cases, the numbers stated are from actual lab tests using the acid digestion method, considered to be the most severe measurement of analyzing content of restricted and banned elements. It is Hitachi's goal to be 100% compliant to European RoHS, including the removal of the Deca-BDE exemption dated July 1, 2008. This cable is REACH Compliant.

Additional Information

Request More Information

Toll Free:
800.772.0116
Phone:
603.669.4347

Hitachi Cable Manchester, Inc.
900 Holt Avenue, East Industrial Park
Manchester, NH 03109