SCSI 25 & 34 pair, 30 AWG Solid & Stranded TC Twisted Pair Cables
|
Basic construction of the SCSI Cable uses 30 gauge (AWG) stranded or solid conductor FRFPO. Conductors are then twisted into pairs with varying left-hand lays to reduce crosstalk. The required number of wire pairs are cabled with a left-hand lay, wrapped with a foam polypro tape, then shielded with both an AL/PET tape (AL side out) and braid shield. The SCSI cable is jacketed with Hi-Flex PVC.†
† Black (000) is standard for this product but other colors are available upon request.
| Series No. | Conductor | Insulation | Nom. Primary OD | Tape | Braid | Drain | Jacket | |
| Inches | mm | |||||||
| 49251 | 30 AWG 7/38 TC |
Flame Retardant Cellular Polyolefin |
0.028 | 0.710 | 100% Polypro Tape & AL/PET |
85% Coverage 36 AWG |
N/A | PVC Matte Black† |
| 49409 | 0.0265 | 0.678 | ||||||
| 49557 | 30 AWG 1/30 TC |
0.0265 | 0.678 | |||||
| 40427 | 0.025 | 0.635 | 85% Coverage 38 AWG |
|||||
| Series No. | Conductor Resistance Ω/Mft. @20°C |
Capacitance | Nom. SE Imp. (Ω) |
Diff** Imp. (Ω) |
Prop. Nom. | Delay Skew | |
| pf/ft. (G-S) | pf/ft (G-S-G) | ns/ft. | Max Delta ns/ft |
||||
| 49251 | 106 | 9 | 17 | 90 | 130 | 1.45 | 0.045 |
| 49409 | 106 | 12 | 18.5 | 80 | 123 | 1.40 | 0.045 |
| 49557 | 113 | 10 | 17 | 90 | 130 | 1.36 | 0.025 |
| 40427 | 104 | 11 | 18 | 90 | 125 | 1.35 | 0.025 |
| Part No. | No. of Conductors | No. of Pairs |
Core Layout | Jacket OD | Color Code | |
| Inches | mm | |||||
| 49251-50-S-01000 | 50 | 25 | 13-9-3 | 0.366 | 9.296 | Band Marked |
| 49251-68-S-01000 | 68 | 34 | 18-11-5 | 0.402 | 10.211 | Band Marked |
| 49409-50-S-01000 | 50 | 25 | 13-9-3 | 0.340 | 8.636 | Band Marked |
| 49409-68-S-01000 | 68 | 34 | 18-11-5 | 0.370 | 9.398 | Band Marked |
| 49557-50-S-01000 | 50 | 25 | 13-9-3 | 0.340 | 8.636 | Band Marked |
| 49557-68-S-01000 | 68 | 34 | 18-11-5 | 0.370 | 9.398 | Band Marked |
| 40427-68-S-01000 | 68 | 34 | 18-11-5 | 0.354 | 8.992 | Band Marked |
** Measured Shield floating.
| <90ppm | <5ppm | <5ppm | <5ppm | <1000ppm |
| Pb | Cd | Cr+6 | Hg | PBDE's PBB's |
Hitachi Cable Manchester is making every effort to provide Lead free and Cadmium free products to help protect our environment. To this end Hitachi Cable Manchester, Inc. has adopted RoHS (Restriction of Hazardous Substances) as its standard. Hitachi's website Eco-Index is designed to inform the interested user of contents of various restricted or banned elements in terms of parts per million. In most cases, the numbers stated are from actual lab tests using the acid digestion method, considered to be the most severe measurement of analyzing content of restricted and banned elements. It is Hitachi's goal to be 100% compliant to European RoHS, including the removal of the Deca-BDE exemption dated July 1, 2008.
| Region | USA | Global |
| Dist Name | Heilind Electronics | Anixter Wire & Cable EMEA Headquarters |
| Address | 5300 Avion Park Drive | Unit A, The Beacons Birchwood Park, Risley, Warrington |
| City | Highland Heights | Cheshire, WA3 6GP |
| State | OH | N/A |
| Zip | 44143 | N/A |
| Country | USA | England |
| Telephone | +1-440-995-3972 | +44 (0) 1925 848017 |
| Fax | +1-440-473-9330 | +44 (0) 1925 850411 |
| Contact | Contact |