Skip to main content

Hitachi Cable Manchester is an OEM Bulk Cable Manufacturer of Fiber Optic Cable, Premise Cable, Electronic Round Cable, Electronic Ribbon Cable and Custom Wire Cable

Hitachi

bulk cable
Supra 660 Category 6 Wire Cables

Supra 660 Enhanced UTP Category 6 Cable

RoHS Compliant Cat 6 CablesBulk Plenum and Riser Cat6 Wire Cable

  • Tested from 1 to 660 MHz
  • Offers Guaranted Headroom to TIA and ISO Category 6 Requirements

Insertion Loss: +3 %
NEXT Loss: +9 dB
PSNEXT Loss: +9 dB
ACRF: +8 dB
PS ACRF: +8dB
Return Loss: n/a
Delay Skew: +20 ns


  • Features
  • Description
  • Applications
  • Transmission Specifications
  • Electrical Characteristics

Supra 660 Wire Cable Features

  • 1,000 ft (305 meters) Reels
  • CMP-50 Rated Cables Available
  • Available in a 4-pair Construction
Diagram of Category 6 Supra 660 Wire Cables
Dielectric Materials Riser Plenum
Primary Insulation Polyolefin FEP
Overall Jacket Flame-Retardant Thermoplastic Low-Smoke, Flame-Retardant Thermoplastic
Star Filler Flame-Retardant Thermoplastic Plenum-Rated Polymer

Supra 660 Plenum Wire Cable Description

(c(UL)us Listed Type CMP, CSA Type FT6)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
30016-8 4 .235 (5.96) 26.0 (11.79)

Supra 660 Riser Wire Cable Description

(c(UL)us Listed Type CMR, CSA Type FT4)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
30022-8 4 .240 (6.09) 23.0 (10.43)

Supra 660 Wire Cable Applications

  • Voice
  • T1 Fractional
  • IBM Type 3 – 1 Mbps
  • 4/16 Mbps Token Ring
  • 10BASE-T Ethernet
  • 100BASE-T4 Fast Ethernet
  • 25.6 Mbps ATM
  • 100 VG – Any LAN
  • All other applications developed for operation over Category 3 or class C cabling
  • 100 Mbps TP-PMD
  • 155 Mbps ATM
  • 270 Mbps Digital Video
  • Broadband Video
  • 100BASE-TX Fast Ethernet
  • 1000BASE-T Gigabit Ethernet
  • All other applications developed for operation over Category 5e or class D cabling
  • 1000 Mbps ATM (CBIG)
  • TIA/EIA-854 Gigabit Ethernet over Category 6 cabling
  • 10GBASE-T
  • All other applications developed for operation over Category 6 or class E cabling

Supra 660 Wire Cable Transmissions Specifications

Download PDF Description of Supra 660 Category 6 Wire Cables

Ins. LossNEXTPSNEXTACRPSACRACRFPSACRFReturn Loss
Freq. (MHz)Std.Max.Std.Min.Std.Min.Cal.Min.Cal.Min.Std.Min.Std.Min.Std.Min.
12.02.074.383.372.381.372.381.370.379.367.875.864.872.820.020.0
43.83.765.374.363.372.361.570.659.568.655.863.852.860.823.024.2
85.35.260.869.858.867.855.564.653.562.649.757.746.754.724.526.3
106.05.859.368.357.366.353.362.551.360.547.855.844.852.825.027.0
167.67.356.265.254.263.248.657.946.655.943.751.740.748.725.027.0
31.2510.710.451.960.949.958.941.250.539.248.537.945.934.942.923.625.9
62.515.414.947.456.445.454.432.041.530.039.531.939.928.936.921.524.2
10019.819.244.353.342.351.324.534.122.532.127.835.824.832.820.123.1
15525.224.441.150.439.448.415.926.014.324.024.032.21.029.018.822.0
20029.028.139.848.837.846.810.820.78.818.721.829.818.826.818.021.4
25032.831.938.347.336.345.35.515.43.513.419.827.816..824.817.320.9
300-35.3-46.1-44.1-10.8-8.8-26.3-23.3-20.4
350-38.6-45.1-43.1-6.5-4.5-24.9-21.9-20.1
400-41.7-44.3-42.3-2.6---23.8-20.8-19.7
500-47.5-42.8-40.8-----21.8-18.8-19.2
555-50.5-42.1-40.1-----20.9-17.9-18.9
660-55.9-41.0-39.0-----19.4-16.4-18.5

*Frequencies beyond the TIA and ISO requirements are for information only.

Bulk Supra 660 Wire Cable Electrical Characteristics

Input Impedance: 100 ± 15Ω (.772 to 250 MHz)
Maximum Conductor Resistance: 9.38 Ω/100 meters @ 20°C
Maximum Resistance Unbalance: 5%
Maximum Capacitance Unbalance: 330 pF/100 meters
Maximum Delay Skew: 25 ns/100 meters
Nominal Velocity of Propagation (NVP): Riser, 68%; Plenum, 70%

Additional Information

Request More Information

Toll Free:
800.772.0116
Phone:
603.669.4347

Hitachi Cable Manchester, Inc.
900 Holt Avenue, East Industrial Park
Manchester, NH 03109