Category 5e GoldLan Hybrid Wire Cables

Category 5e GoldLAN™ Hybrid Cable

RoHS Compliant Cat 5e CablesBulk Plenum and Riser Cat5e Wire Cable

  • Tested from 1 to 100 MHz
  • Component Compliant to TIA Category 5e Cable Requirements
  • Power Sum Compliance Ensures Minimum Signal Corruption Due to Alien Crosstalk

  • Features
  • Description
  • Applications
  • ransmission Specifications
  • Electrical Characteristics

Category 5e Hybrid Wire Cable Features

  • 1,000 ft (305 meters) Reels
  • Custom Internal Jacket Colors Available
  • Available in 2, 3, 4 and 6 leg Construction
Diagram of Unshielded Category 5e Hybrid Wire Cables
Dielectric Materials Riser
Primary Insulation Polyolefin
Overall Jacket Flame-Retardant Thermoplastic
Central Filler Flame-Retardant Thermoplastic

Category 5e Hybrid Riser Wire Cable Description

(c(UL)us Listed Type CMR, CSA Type FT4)
Part No. No. of Legs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
38886-16 2 Legs x 4-pair .215 x .430 (5.5 x 10.9) 58 (26)
38886-24 3 Legs x 4-pair .460 x .430 (11.7 x 10.9) 84 (38)
38886-32 4 Legs x 4-pair .510 x .430 (13.0 x 10.9) 107 (49)
38886-48 6 Legs x 4-pair .620 x .430 (15.7 x 10.9) 168 (76)

Category 5e Hybrid Wire Cable Applications

  • Voice
  • T1 Fractional
  • IBM Type 3 – 1 Mbps
  • 4/16 Mbps Token Ring
  • 10BASE-T Ethernet
  • 100BASE-T4 Fast Ethernet
  • 25.6 Mbps ATM
  • 100 VG – Any LAN
  • All other applications developed for operation over Category 3 or class C cabling
  • 100 Mbps TP-PMD
  • 155 Mbps ATM
  • 270 Mbps Digital Video
  • Broadband Video
  • 100BASE-TX Fast Ethernet
  • 1000BASE-T Gigabit Ethernet

Category 5e Hybrid Wire Cable Transmissions Specifications

Download PDF Description of Unshielded Category 5e GoldLAN Hybrid Cable

Frequency
(MHz)
Ins. Loss
(dB/100 m)
NEXT
loss (dB)
PSNEXT
loss (dB)
ACR
(dB)
PSACR
(dB)
ACRF
(dB)
PSACRF
(dB)
Return Loss
(dB)
1 2.0 65.3 62.3 63.3 60.3 63.8 60.8 20.0
4 4.1 56.3 53.3 52.2 49.2 51.8 48.8 23.0
8 5.8 51.8 48.8 46.0 43.0 45.7 42.7 24.5
10 6.5 50.3 47.3 43.8 40.8 43.8 40.8 25.0
16 8.2 47.2 44.2 39.0 36.0 39.7 36.7 25.0
31.25 11.7 42.9 39.9 31.2 28.2 33.9 30.9 23.6
62.5 17.0 38.4 35.4 21.4 18.4 27.9 24.9 21.5
100 22.0 35.3 32.3 13.3 10.3 23.8 20.8 20.1

Bulk Category 5e Hybrid Wire Cable Electrical Characteristics

Input Impedance: 100 ± 15Ω (.772 to 100 MHz)
Maximum Resistance Unbalance: 5%
Maximum Capacitance Unbalance: 330 pF/100 meters
Maximum Delay Skew: 45 ns/100 meters
Nominal Velocity of Propagation (NVP): riser, 68%; plenum, 70%