Skip to main content

Hitachi Cable Manchester is an OEM Bulk Cable Manufacturer of Fiber Optic Cable, Premise Cable, Electronic Round Cable, Electronic Ribbon Cable and Custom Wire Cable

Hitachi

bulk cable
Category 3 Power Sum Multi-Pair Wire Cable

Category 3 Power Sum Multi-Pair Cable

RoHS Compliant Cat 3 CablesBulk Plenum and Riser Cat3 Wire Cable

  • Tested from 1 to 16 MHz
  • Component Compliant to TIA Category 3 Power Sum Backbone Cable Requirements
  • Power Sum Compliance Ensures Minimum Signal Corruption Due to Alien Crosstalk

  • Features
  • Description
  • Applications
  • Transmission Specifications
  • Electrical Characteristics

Category 3 Power Sum Wire Cable Features

  • 1,000 ft (305 meters) Reels
  • Available in 25, 50, 100, 200 and 300-pair Constructions
  • Contact Hitachi Cable Manchester for Design and Availability of 400-pair Constructions
Diagram of Category 3 Power Sum Multi-Pair Wire Cable
Dielectric Materials Riser Plenum
Primary Insulation PVC Low Smoke, Flame-Retardant Thermoplastic
Overall Jacket (<100-pair) Flame-Retardant Thermoplastic Low Smoke, Flame-Retardant Thermoplastic
Overall Jacket (≥100-pair) Flame-Retardant Thermoplastic PvDF

Category 3 Power Sum Plenum Wire Cable Description

(c(UL)us Listed Type CMP, CSA Type FT6)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
30134-50 25 .38 (9.7) 106.0 (48.1)
30134-100 50 .20 x .50 (5.1 x 12.7) 197.0 (89.3)
38779-200 100 .69 (17.5) 399.0 (180.9)
38779-400 200 .97 (24.6) 807.0 (366.0)
38779-600 300 1.328 (33.7) 1196.0 (542.4)

Category 3 Power Sum Riser Wire Cable Description

(c(UL)us Listed Type CMR, CSA Type FT4)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
39228-50 25 .38 (9.7) 100 (45.4)
39288-100 50 .20 x .50 (5.1 x 12.7) 194.0 (88.0)
39288-200 100 .69 (17.5) 380.0 (172.3)
39228-400 200 .97 (24.6) 751.0 (340.6)
39228-600 300 1.26 (32.0) 1100.0 (498.9)

Category 3 Power Sum Wire Cable Applications

  • Voice
  • T1 Fractional
  • IBM Type 3 – 1 Mbps
  • 4/16 Mbps Token Ring
  • 10BASE-T Ethernet
  • 100BASE-T4 Fast Ethernet
  • 25.6 Mbps ATM
  • 100 VG – Any LAN
  • All other Applications Developed for Operation over Category 3 or Class C Cabling

Category 3 Power Sum Wire Cable Transmissions Specifications

Download PDF Description of Category 3 Power Sum Multi-Pair Wire Cable

Frequency
(MHz)
Ins. Loss
(dB/100 m)
NEXT Loss
(dB)
ACR
(dB)
Structural
Return Loss
(dB)
1 2.6 41.3 38.7 12.0
4 5.6 32.3 26.7 12.0
8 8.5 27.8 19.3 12.0
10 9.7 26.3 16.6 12.0
16 13.1 23.2 10.1 10.0

Bulk Category 3 Power Sum Wire Cable Electrical Characteristics

Characteristic Impedance: 100 ± 15Ω (.772 to 16 MHz)
Maximum Resistance Unbalance: 5%
Maximum Capacitance Unbalance: 330 pF/100 meters
Maximum Delay Skew: 45 ns/100 meters