Skip to main content

Hitachi Cable Manchester

Hitachi

bulk cable
Shielded Category 5e Cable Wire

Shielded Category 5e Premise Cable

RoHS Compliant Category 5e CablesBulk Plenum and Riser Cat5E Wire Cable

  • Tested from 1 to 400 MHz
  • Component Compliant to TIA Category 5e Cable Requirements

  • Features
  • Description
  • Applications
  • Transmission Specifications
  • Electrical Characteristics

Shielded Category 5e Wire Cable Features

  • 1,000 ft (305 meters) Reels
  • Available in a 2, 3 and 4-pair Constructions
Diagram of Shielded Category 5e Cable
Dielectric Materials Riser Plenum
Primary Insulation Polyolefin FEP
Overall Jacket Flame-Retardant Thermoplastic Low-Smoke, Flame-Retardant Thermoplastic

Category 5e Plenum Wire Cable Description

(c(UL)us Listed Type CMP, CSA Type FT6)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
38653-4 2 .229 (5.82) 20.4 (9.3)
38653-6 3 .238 (6.05) 25.2 (11.4)
38653-8 4 .255 (6.48) 30.6 (13.9)

Category 5e Riser Wire Cable Description

(c(UL)us Listed Type CMR, CSA Type FT4)
Part No. Pairs Cable OD
in (mm)
Weight
lbs/1000ft (kg/305m)
39092-4 2 .229 (5.82) 17.0 (7.7)
39092-6 3 .238 (6.05) 21.0 (9.6)
39092-8 4 .255 (6.48) 25.0 (11.4)

Shielded Category 5e Wire Cable Applications

  • Voice
  • T1 Fractional
  • IBM Type 3 – 1 Mbps
  • 4/16 Mbps Token Ring
  • 10BASE-T Ethernet
  • 100BASE-T4 Fast Ethernet
  • 25.6 Mbps ATM
  • 100 VG – Any LAN
  • All other applications developed for operation over Category 3 or class C cabling
  • 100 Mbps TP-PMD
  • 155 Mbps ATM
  • 270 Mbps Digital Video
  • Broadband Video
  • 100BASE-TX Fast Ethernet
  • 1000BASE-T Gigabit Ethernet

Shielded Category 5e Wire Cable Transmissions Specifications

Download PDF Description of Shielded Category 5e Wire Cable

Ins. LossNEXTPSNEXTACRPSACRACRFPSACRFReturn Loss
Freq. (MHz)Std.Max.Std.Min.Std.Min.Cal.Min.Cal.Min.Std.Min.Std.Min.Std.Min.
12.02.065.365.362.362.362.963.359.960.363.863.860.860.820.020.0
44.14.156.356.353.353.351.452.248.449.251.851.848.848.823.023.0
85.85.851.851.848.848.844.946.041.943.045.745.742.742.724.524.5
106.56.550.350.347.0347.342.543.839.540.843.843.840.840.825.025.0
168.28.247.247.244.244.237.339.034.336.039.739.736.736.725.025.0
31.2511.711.745.842.939.939.928.831.225.828.233.933.930.930.923.623.6
62.517.017.044.338.435.435.418.021.415.018.427.927.924.924.921.521.5
10022.022.035.335.332.332.38.913.35.910.323.823.820.820.820.120.1
155-28.1-32.4-29.4-4.3-1.3-20.0-17.0-18.8
200-32.4-30.8-27.8-----17.8-14.8-18.0
250-36.9-29.3-26.3-----15.8-12.8-17.3
400-48.5-26.3-23.3-----11.8-8.8-15.9

*Frequencies beyond the TIA and ISO requirements are for information only.

Bulk Shielded Category 6 Wire Cable Electrical Characteristics

Input Impedance: 100 ± 15Ω (0.772 to 100 MHz)
Maximum Resistance Unbalance: 5%
Maximum Capacitance Unbalance: 330 pF/100 meters
Maximum Delay Skew: 45 ns/100 meters
Nominal Velocity of Propagation (NVP): riser: 68%; plenum: 70%

Additional Information

Request More Information

Toll Free:
800.772.0116
Phone:
603.669.4347

Hitachi Cable Manchester, Inc.
900 Holt Avenue, East Industrial Park
Manchester, NH 03109